ISOMIL-T - Mineral Insulated Thermocouple Cables
In ISOMIL-T the thermoelectric voltages of the thermocouples are in accordance with the basic standard values within the usual tolerance range. For NiCr-Ni the basic values of the thermoelectric voltage are identical in the German and international standards. For both Fe-CuNi (Thermoiron-Thermoconstantan) and Cu-CuNi (Thermocopper-Thermoconstantan) they differ.
These thermocouples are available in ISOMIL-T in accordance with the German Standard Norm DIN 43710 and with the International Thermoelectric Voltage Series (IEC 584).
The limit deviation of the thermocouple voltage is available according the following norm:
• DIN IEC 584-2
• ASTM E 230-93 / ANSI.MC.96.1
Other norms, e.g. GOST on request.
Type denotation ISOMIL-T
Example: The type Denotation 2K2A30 designates a cable coil with 2 cores, inner conductors made of NiCrNi, insulation made of MgO (≥ 97%), the sheath material 1.4541 and an outer diameter of 3 mm.
| Number of conductors | Inner conductor | Insulation | Sheath material | Outer diameter (1/10 mm) |
| 2 2-cores | K NICrNi | 1 AI²O³ (97%) | A 1.4541 | |
| 4 4-cores | E NiCr-CuNi | 2 MgO (≥ 97%) | F 1.4571 | |
| 6 6-cores | J Fe-CuNi | 3 MgO (99,4%) | L 2.4816 | |
| 8 8-cores | T Cu-CuNi | C 2.4851 | ||
| U Cu-CuNi | G 2.4858 | |||
| S PtRh10%-Rh | P 2.4951 | |||
| R PtRh13%-Rh | Q 1.4845 | |||
| N Nicrosil-Nisil | R 1.4301 | |||
| S 1.4404 | ||||
| X 1.4876 | ||||
| NC Incotherm TG |